78 resultados para LUNG

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In patients with acute respiratory distress syndrome, positive end-expiratory pressure is associated with alveolar recruitment and lung hyperinflation despite the administration of a low tidal volume. The best positive end-expiratory pressure should correspond to the best compromise between recruitment and distension, a condition that coincides with the best respiratory elastance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare the efficiency of an Aeroneb Pro vibrating plate and an Atomisor MegaHertz ultrasonic nebulizer for providing ceftazidime distal lung deposition.Design: In vitro experiments. One gram of cetazidime was nebulized in respiratory circuits and mass median aerodynamic diameter of particles generated by ultrasonic and vibrating plate nebulizers was compared using a laser velocimeter. In vivo experiments. Lung tissue concentrations and extrapulmonary depositions were measured in ten anesthetized ventilated piglets with healthy lungs that received 1 g of ceftazidime by nebulization with either an ultrasonic (n = 5), or a vibrating plate (n = 5) nebulizer.Setting: A two-bed Experimental Intensive Care Unit of a University School of Medicine.Intervention: Following sacrifice, 5 subpleural specimens were sampled in dependent and nondependent lung regions for measuring ceftazidime lung tissue concentrations by high-performance liquid chromatography.Measurements and results: Mass median aerodynamic diameters generated by both nebulizers were similar with more than 95% of the particles between 0.5 and 5 mu m. Lung tissue concentrations were 553 +/- 123 [95% confidence interval: 514-638] mu g g(-1) using ultrasonic nebulizer, and 452 +/- 172 [95% confidence interval: 376-528] mu g g(-1) using vibrating plate nebulizers (NS). Extrapulmonary depositions were, respectively, of 38 +/- 5% (ultrasonic) and 34 +/- 4% (vibrating plate) (NS).Conclusions: Vibrating plate nebulizer is comparable to ultrasonic nebulizers for ceftazidime nebulization. It may represent a new attractive technology for inhaled antibiotic therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose of reviewLung ultrasound at the bedside can provide accurate information on lung status in critically ill patients with acute respiratory distress syndrome.Recent findingsLung ultrasound can replace bedside chest radiography and lung computed tomography for assessment of pleural effusion, pneumothorax, alveolar- interstitial syndrome, lung consolidation, pulmonary abscess and lung recruitment/de-recruitment. It can also accurately determine the type of lung morphology at the bedside (focal or diffuse aeration loss), and therefore it is useful for optimizing positive end-expiratory pressure. The learning curve is brief, so most intensive care physicians will be able to use it after a few weeks of training.SummaryLung ultrasound is noninvasive, easily repeatable and allows assessment of changes in lung aeration induced by the various therapies. It is among the most promising bedside techniques for monitoring patients with acute respiratory distress syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. The best way to study compensatory lung growth (CLG) is in a transplant without rejection. Since immunosuppressive drugs may influence CLG, it is better to not use them. Therefore we studied CLG in a reimplant of only one lobe after its removal. The objective was to compare lobar transplant CLG with CLG after lobectomy.Methods. Forty eight dogs were distributed in three groups: G1 = control, G2 = left cranial lobectomy, and G3 = left pneumonectomy with reimplantation of the caudal lobe. Five months after surgery the animals underwent lung scintigraphy and were sacrificed for morphometric study.Results. There was no correlation between scintigraphy and lung mass or lung volume. There was both mass and residual volume CLG in the operated groups, both contralateral and ipsilateral to surgery. There was no compensation for total lung capacity or compliance in the remaining caudal lobe (G2) or the reimplanted caudal lobe (G3) at 5 months after surgery. There was more damage in the reimplanted lobe. As previous studies have shown that CLG starts with increased mass and residual volume and compliance is compensated later. This study seemed to document the beginning of CLG, with lung compliance being the limiting factor of CLG at 5 months.Conclusion. There was CLG in both the reimplanted lobe and the contralateral lung, but compliance was still reduced. CLG was similar in both groups, but in the implanted lobe compliance was more prejudiced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scorpaena plumieri venomous fish inflicted severe injuries in humans characterized by systemic effects and cardiovascular abnormalities. Although cardiotoxic and hypotensive effects induced in rats by this venom have been studied, little is known about their effect on bronchial epithelial permeability and airway inflammation in mice. The primary goal of this study was to determine whether the intraplantar or intraperitoneal injection of S. plumieri venom results in systemic response, and whether this event initiates acute lung injure. We found that BALB/c mice developed neutrophilic infiltrates, areas of lung hemorrhage and alveolar macrophage activation within 24 h after injection with S. plumieri venom. These histopathological changes were associated with an early increase in BAL fluid protein and early induction of cytokines, chemokines and matrix metaloproteinases, followed by a later increase in BAL fluid neutrophils. These findings provide clear evidence that the injection of S. plumieri venom in footpad or peritoneal cavity of mice results in venom deposition in the airway and initiates a sustained inflammatory response in the lungs. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To evaluate the influence of glycemic control on fetal lung maturity in pregnancies affected by diabetes or mild hyperglycemia. Design. Cross-sectional study. Setting. Level III maternity center. Population. A total of 187 pregnant women were submitted to routine amniocentesis for the assessment of fetal lung maturity up to 72 hours before delivery. Methods. Fetal lung maturity thresholds were: Clements-positive at a dilution of 0.5; OD(650) nm >= 0.15; and lamellar body count (LBC) >= 32,000/mu l. The relation of test results with adequate (<= 6.7 mmol/l) or poor (> 6.7 mmol/l) glycemic mean (GM) at term and at preterm was evaluated. Main outcome measure. Delay in fetal lung maturity when glycemic control was poor. Results. Glycemic control was adequate in 146 (78.1%) women. Clements maturity rates were higher at term (91.9%) than at preterm (64.7%) when GM <= 6.7 mmol/l (p < 0.001), but not when control was inadequate. LBC median was higher at term (99.0; 62.0-154.0) than at preterm (66.5; 40.5-108.25) (p = 0.009) when GM <= 6.7 mmol/l, while GM > 6.7 mmol/l did not lead to any difference between these rates at term or preterm. When glycemic control was adequate, OD(650) nm medians at term and at preterm were similar. However, when GM > 6.7 mmol/l, OD(650) nm median at term (0.29; 0.22-0.40) was higher than that observed at preterm (0.15; 0.12-0.18) (p < 0.001). Conclusions. Our results suggest that in term pregnancies routine amniocentesis for the assessment of fetal lung maturity should be abandoned. In preterm pregnancies, or when glycemic control is inadequate it is recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Verificar se os testes: Volume Expiratório Forçado no 1º segundo (VEF1), Teste de Caminhada de 6 minutos (TC6) e Teste de Escada (TE) se alteram proporcionalmente ao pulmão funcionante ressecado. MÉTODOS: Foram incluídos pacientes candidatos a toracotomia para ressecção pulmonar. No pré-operatório (pré) e no mínimo três meses após a cirurgia (pós), realizaram espirometria, TC6 e TE. O TE foi realizado em escada com 12,16m de altura. O tempo para subir todos os degraus o mais rápido possível foi chamado tempo de escada (tTE). Os cálculos dos valores dos testes preditos para o pós-operatório (ppo) foram realizados conforme o número de segmentos funcionantes perdidos. Os valores pré, ppo e pós foram comparados entre si para cada teste. Estatística: foi utilizada a análise de variância para medidas repetidas (ANOVA), com significância de 5%. RESULTADOS: Foram estudados 40 pacientes. A ressecção pulmonar variou desde o ganho de dois segmentos funcionantes até a perda de 9. Os valores pré, ppo e pós foram respectivamente: VEF1 -pré = 2,6±0,8L, ppo = 2,3±0,8L, pós = 2,3±0,8L (VEF1pré > VEF1ppo = VEF1pós), TC6-pré = 604±63m, ppo = 529±103m, pós = 599±74m (TC6pré = TC6pós > TC6ppo), tTE-pré = 32,9±7,6s, ppo = 37,8±12,1s, pós = 33,7±8,5s (tTEpré = tTEpós < tTEppo). CONCLUSÃO: Nas ressecções pulmonares, este grupo de pacientes perdeu função pulmonar medida através da espirometria, mas não perdeu a capacidade de exercício, medida através dos testes de escada e caminhada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Investigar os efeitos morfológicos da exposição crônica à inalação de fumaça do tabaco e o do consumo de álcool nos pulmões e no crescimento de ratos. MÉTODOS: Sessenta ratos Wistar machos foram distribuídos em quatro grupos: controle, tabaco, álcool e tabaco + álcool, e acompanhados por um período de 260 dias. No final do periodo foi realizada análise morfológica dos pulmões por microscopia óptica e eletrônica. O crescimento dos ratos foi investigado através da medição do comprimento focinho-ânus, peso corporal e índice de massa corporal. RESULTADOS: Os três grupos expostos às drogas apresentaram peso e comprimento significativamente menores que os do grupo controle. As percentagens de bronquiolite e alveolite, e o diâmetro alveolar médio foram maiores nos grupos expostos à fumaça do tabaco, mas sem significancia estatística quando comparadas ao grupo controle. A microscopia eletrônica revelou apoptose mais intensa e lesões degenerativas no grupo de fumantes, enquanto lesões degenerativas nos corpos lamelares foram mais intensas com a associação de ambas as drogas. CONCLUSÕES: Este modelo experimental mostrou alterações morfológicas observadas por microscopia eletrônica, principalmente devido à exposição ao tabaco. Tanto o alcool como o tabaco prejudicaram o crescimento dos animais, o tabaco mostrando um efeito maior sobre o comprimento e o álcool sobre o peso corporal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)